Protego BR

P/EBR

Pressure Relief Valve deflagration- and endurance burning-proof

Features

10% Technology
for Minimum Pressure Increase up to Full Lift
Extreme Tightness
Resulting in Lowest Possible Product Losses and Reduced Environmental Pollution
Optimal Pressure Maintenance
Set Pressure Close to Opening Pressure for Optimum Pressure Maintenance in the System
Guided Valve Pallet
Valve Pallet Is Guided Inside the Housing to Protect Against Harsh Weather Conditions
Protective System According to ATEX
can Be Used as a Protective System in Areas With Potentially Explosive Atmosphere in Accordance With ATEX
Safety Against Endurance Burning
Protection against Atmospheric Deflagration and Endurance Burning
Intergrated Flame Arrester
Integrated PROTEGO® Flame Arrester Unit Saves Space and Weight and Reduces Costs
Modular Design
Allows Replacement and Cleaning of Single FLAMEFILTER®
Function and Description

Combined Pressure and Vacuum Relief Valve

The Deflagration-Proof and Endurance-Burning-Proof PV/EBR Type PROTEGO® valve is a highly developed combined pressure/ vacuum relief valve for high flow capacities with an integrated Flame Arrester. It is primarily used as a device for flame transmission-proof in-breathing and out-breathing on tanks, containers, and process equipment. The valve offers reliable protection against overpressure and vacuum, prevents the in-breathing of air and product losses almost up to the set pressure, and protects against atmospheric deflagration and endurance burning if stabilized burning occurs.

For Explosion Groups IIA to IIB3

The PROTEGO® Flame Arrester Unit is designed to achieve minimum pressure drop with maximum safety. PROTEGO® PV/EBR valves are available for substances from explosion groups IIA to IIB3 (NEC group D to C MESG ≥ 0.65 mm). The valve functions proportional, so the set pressures should be selected in relation to the proportional behavior (such as a 10%, 40%, or 100% overpressure from the set pressure to the relieving pressure at which the required flow performance is reached).

Advanced Manufacturing Technology

The tank pressure is maintained up to the set pressure with a tightness that is above the normal standards due to our state-of-the-art manufacturing technology. This feature is ensured by the valve seats made of high quality stainless steel and with individually lapped valve pallets (1), or with an air cushion seal (2), in conjunction with high quality FEP diaphragm. The valve pallets are also available with a PTFE seal to prevent the valve pallets from sticking when sticky substances are used and to enable the use of corrosive fluids. After the overpressure is released, the valve re-seats and provides a tight seal.

Main Component – PROTEGO® Flame Arrester Unit

If the set pressure is exceeded, explosive gas/product vapor/air mixtures are released into the atmosphere. If this mixture ignites, the integrated PROTEGO® Flame Arrester Unit (3) prevents flame transmission into the tank. If additional mixture continues to flow and stabilized burning occurs, the integrated Flame Arrester Unit prevents flashback as a result of endurance burning. The valve is protected and also fulfils its function under these severe conditions. The spring-loaded weather hood opens as soon as the melting element (4) melts.

Many Individual Certifications

The valve can be used at an operating temperature of up to +60°C / 140°F and meets the requirements of European Tank Design Standard EN 14015 (Appendix L) and ISO 28300 (API 2000). EU conformity according to the currently valid ATEX directive. Approvals according to other national/international regulations on request.
Product Data

Dimensions

To select the nominal size (DN), please use the flow capacity chart on the following page

DN 80 / 3" 80 / 3" 100 / 4" 100 / 4"
DN 3" 3" 4" 4"
Set pressure ≤ +80 mbar > +80 mbar ≤ +80 mbar > +80 mbar
Set pressure ≤ +32.1 inch W.C. > +32.1 inch W.C. ≤ +32.1 inch W.C. > +32.1 inch W.C.
a 353 353 353 353
b 345 505 345 505

Dimensions in mm / inches

Dimensions for pressure relief valve with heating jacket upon request

Selection of explosion group

MESGExpl. Gr. (IEC / CEN)Gas Group (NEC)
> 0,90 mmIIAD
≥ 0,65 mmIIB3C

Special approvals upon request

Material selection for housing

Design  BC
HousingSteelStainless Steel
Heating jacket (P / EBR-H-...)SteelStainless Steel
Valve seatStainless SteelStainless Steel
Weather hoodSteelStainless Steel

Special materials upon request

Material combinations of flame arrester unit

Design A
FLAMEFILTER® cageStainless Steel
FLAMEFILTER®Stainless Steel
SpacerStainless Steel

Special materials upon request

Material selection for valve pallet

Design ABCD
Pressure range [mbar]
[inch W.C.]
+3.5 up to +5.0
+1.4 up to +2.0
>+5.0 up to +14
>+2.0 up to +5.6
>+14 up to +210
>+5.6 up to +84
>+14 up to +210
>+5.6 up to +84
Valve palletAluminiumStainless SteelStainless SteelStainless Steel
SealingFEPFEPMetal to MetalPTFE

Special materials and higher pressure settings upon request

Flange connection type

EN 1092-1; Form B1
ASME B16.5 CL 150 R.F.

other types upon request

Flow Capacity Chart

The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). For conversion to other densities and temperatures refer to Sec. 1: “Technical Fundamentals”.

Detail X

Detail X