UB/DF
Pressure Diaphragm Valve deflagration- and endurance burning-proof

Features
Extreme Tightness
Optimal Pressure Maintenance
Flow Capacity
Digital Level Monitoring
Digital Level Sensors
Safe Venting
Frost-Proof
Condensate Drainage
Monitoring
Modular Design
Suitable for Challenging Applications
Easy Operation Monitoring
Protective System According to ATEX
Safety Against Endurance Burning

Highly Developed Pressure Relief Valve

For Explosion Group IIB3

Operation of the Overpressure Relief Valves
Overpressure Protection with Advanced Sealing Technology
Dynamic Flame Arresting at Overpressure Conditions
Main Component – PROTEGO® Flame Arrester Unit
Many Individual Certifications
Dimensions
To select the nominal size (DN), please use the flow capacity charts on the following pages
| DN | pressure | pressure | 80 / 3" | pressure | pressure | 100 / 4" | pressure | pressure | 150 / 6" |
| a | up to +28 mbar | up to +11.2 inch W.C. | 615 / 24.21 | up to +28 mbar | up to +11.2 inch W.C. | 645 / 25.39 | up to +25 mbar | up to +10 inch W.C. | 680 / 26.77 |
| a | > +28 mbar | > +11.2 inch W.C. | 765 / 30.12 | > +28 mbar | > +11.2 inch W.C. | 795 / 31.30 | > +25 mbar | > +10 inch W.C. | 830 / 32.68 |
| b | 410 / 16.14 | 485 / 19.09 | 590 / 23.23 |
Dimensions in mm / inches
Pressure settings > +50 mbar / +20 inch W.C. (DN 80/3”), > +45 mbar / +18 inch W.C. (DN 100/4”), > +46 mbar / +18.4 inch W.C. (DN150/6”) with additional liquid reservoir - dimensions upon request
Dimensions for pressure diaphragm valves with heating coil upon request
Selection of explosion group
| MESG | Expl. Gr. (IEC / CEN) | Gas Group (NEC) |
| ≥ 0,65 mm | IIB3 | C |
Special approvals upon request
Material selection for housing
| Design | B | C | D |
| Housing | Cast Iron | Steel | Stainless Steel |
| Valve top | Stainless Steel | Stainless Steel | Stainless Steel |
| Heating coil (UB / DF-H-...) | Stainless Steel | Stainless Steel | Stainless Steel |
| Valve seat | Stainless Steel | Stainless Steel | Stainless Steel |
| Gasket | FPM | FPM | PTFE |
| Diaphragm | A, B | A, B | A, B |
| Flame arrester unit | A | C | C |
Option: Housing with ECTFE-lining
Special materials upon request
Material selection
| Design | A | B |
| Diaphragm | FPM | FEP |
Special materials upon request
Material combinations of flame arrester unit
| Design | A | C |
| FLAMEFILTER® cage | Cast Iron | Stainless Steel |
| FLAMEFILTER® | Stainless Steel | Stainless Steel |
| Spacer | Stainless Steel | Stainless Steel |
Special materials upon request
Flange connection type
| EN 1092-1; Form B1 |
| ASME B16.5 CL 150 R.F. |
other types upon request
Flow Capacity Chart


UB/DF DN100 Pressure


UB/DF DN150 Pressure


The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). For conversion to other densities and temperatures refer to Sec. 1: “Technical Fundamentals”.